560 research outputs found

    Optimum Remedial Operation of Permanent Magnet Synchronous Motor

    Get PDF
    In critical systems, the reliability of the drive is very important. The faults are unwanted. The faults may be lead to loss of the human life and capital. This paper is addressed this problem and suggested two models to solve it. The first model doesn’t contain any special tools to improve the torque ripple and THD. The second model contains 2PI current controllers to improvement the performance at fault and remedial operation. One is for the torque and the other is for the flux. The first PI controller is feeding from the torque error between the reference and estimated torques to get new q-axis current component representing modifier current arises from uncertain things inside the machine and drive system such as temperature and parameters variations. This current will add to reference q-axis current to get robust new q-axis current to satisfy the drive requirement and solve the torque problem (ripple torque). With robust current, the total harmonic distortion is a decrease but doesn’t reach the best value so the other PI controller is used to adjust the THD. In this PI controller, the d-axis flux is compared to rotor permanent magnet flux to solve this problem arises from non-sinusoidal of the magnetic flux. The output of the PI controller is introduced to the reference d-axis current. The new d-axis current will reach the best value of THD. The simulation of the second controller is compared to the simulation of first controller to show if the second controller strong or weak. Matlab simulink is used to simulate the drive system.DOI:http://dx.doi.org/10.11591/ijece.v2i5.72

    An efficient technique for out-of-band power reduction for the eliminated CP-STC-shaped system for 5G requirements

    Get PDF
    The most dominant needs for the recent wireless mobile applications are higher bandwidth (BW) efficiency, higher energy efficiency higher quality of services (QOS). The main technique in 4G systems is OFDM but it suffers from some limitations such as large peak to average power ratio (PAPR), higher Out-of-Band (OOB) power radiation, and wasting bandwidth efficiency due to cyclic prefix (CP) extension. In his paper, these OFDM limitations will be reduced with low computational complexity compared to filter bank multicarriers (FBMC). The proposed scheme is based on symbol time compression (STC) for OFDM system. The proposed STC-Shaped system is achieved via interleaver-spreader and symbol shaper in the transmitter side in addition to equalization and combining processes in the receiver side. Comparative study between the proposed system and the conventional OFDM in case of additive white Gaussian noise (AWGN) and COST 207 typical multipath fading channel will be presented. The numerical results show that the proposed STC-Shaped scheme reduces OOB significantly. The proposed scheme improves BER in multipath Rayleigh fading although it is without CP. Thus, the proposed system is more robust against inter symbol interference (ISI) compared to conventional OFDM system. Also, the numerical results show that the PAPR of the proposed system is decreased significantly and also, it is derived theoretically. Also, the proposed scheme overcomes CP extension, and hence increases the bandwidth (BW) efficiency. Finally, the computational complexity for the proposed scheme is derived and it has very low complexity compared to FBMC. The system performance measurments has been fulfilled using cumulative distribution function (CDF), power spectral density (PSD) and bit error rate (BER)

    Calli Essential Oils Synergize with Lawsone against Multidrug Resistant Pathogens.

    Get PDF
    The fast development of multi-drug resistant (MDR) organisms increasingly threatens global health and well-being. Plant natural products have been known for centuries as alternative medicines that can possess pharmacological characteristics, including antimicrobial activities. The antimicrobial activities of essential oil (Calli oil) extracted from the Calligonum comosum plant by hydro-steam distillation was tested either alone or when combined with lawsone, a henna plant naphthoquinone, against MDR microbes. Lawsone showed significant antimicrobial activities against MDR pathogens in the range of 200-300 µg/mL. Furthermore, Calli oil showed significant antimicrobial activities against MDR bacteria in the range of 180-200 µg/mL, Candida at 220-240 µg/mL and spore-forming Rhizopus fungus at 250 µg/mL. Calli oil's inhibition effect on Rhizopus, the major cause of the lethal infection mucormycosis, stands for 72 h, followed by an extended irreversible white sporulation effect. The combination of Calli oil with lawsone enhanced the antimicrobial activities of each individual alone by at least three-fold, while incorporation of both natural products in a liposome reduced their toxicity by four- to eight-fold, while maintaining the augmented efficacy of the combination treatment. We map the antimicrobial activity of Calli oil to its major component, a benzaldehyde derivative. The findings from this study demonstrate that formulations containing essential oils have the potential in the future to overcome antimicrobial resistance

    Effect of geometrical properties on strength of externally prestressed steel-concrete composite beams

    Get PDF
    A parametric study was carried out to investigate the structural behaviour of composite steel-concrete T-beams under different prestressing conditions. The studied parameters include different cases of loading, tendon profiles, beam spans, initial prestressing levels and different dimensions of steel sections and concrete deck. The studied beams were modelled by the finite-element software Ansys. The effect of three geometrical parameters was investigated for three different tendon profiles. It was found that straight tendon profiles are more appropriate for beams under distributed loads, whereas a draped tendon profile is more convenient for beams under concentrated loads. In addition, the ratio of the tension flange area to the compression flange area is the most effective geometrical parameter on the ultimate resistance of the studied prestressed beams. For instance, increasing this ratio from 1 to 3 resulted in increasing the additional resistance of the beam due to prestressing from 15·4 to 46·1%. For composite beams, the presence of the concrete slab prevented the lateral-torsional buckling and accordingly minimised the effect of the span. Moreover, increasing the slab thickness-to-width ratio resulted in enhancing the average increase in beam strength from 13·5 to 19·9%

    A NOVEL SIMPLE AND HIGHLY SECURE METHOD FOR DATA ENCRYPTION-DECRYPTION

    Get PDF
    In the course of the past 30 years, data has become pivotal to all aspects of human life. Data generated, captured, and replicated are increasing in size and expanding applications. The proliferation of fast wireless networks has encouraged data storage within the cloud. So, protecting data from attackers has become urgent to maintain its security and confidentiality, need for security and privacy technologies, systems, and processes to address it. This research paper proposes a simple and highly secure encryption decryption (SHSED) algorithm that can be used for cloud computing-based applications. It achieves the Shannon’s concept of diffusion and confusion by the involvement of logical operations, such as XORing, addition, and subtraction in addition to byte shifting. It is also characterized by the flexibility in the secret key length and the number of rounds. Experimental results have demonstrated powerful security level and a clear improvement in the encryption execution time measurements and security strength as compared with cryptosystems widely used in cloud computing

    Improving the efficiency of the cardiac catheterization laboratories through understanding the stochastic behavior of the scheduled procedures

    Get PDF
      Background: In this study, we sought to analyze the stochastic behavior of Catherization Labora­tories (Cath Labs) procedures in our institution. Statistical models may help to improve estimated case durations to support management in the cost-effective use of expensive surgical resources. Methods: We retrospectively analyzed all the procedures performed in the Cath Labs in 2012. The duration of procedures is strictly positive (larger than zero) and has mostly a large mini­mum duration. Because of the strictly positive character of the Cath Lab procedures, a fit of a lognormal model may be desirable. Having a minimum duration requires an estimate of the threshold (shift) parameter of the lognormal model. Therefore, the 3-parameter lognormal model is interesting. To avoid heterogeneous groups of observations, we tested every group-car­diologist-procedure combination for the normal, 2- and 3-parameter lognormal distribution. Results: The total number of elective and emergency procedures performed was 6,393 (8,186 h). The final analysis included 6,135 procedures (7,779 h). Electrophysiology (intervention) pro­cedures fit the 3-parameter lognormal model 86.1% (80.1%). Using Friedman test statistics, we conclude that the 3-parameter lognormal model is superior to the 2-parameter lognormal model. Furthermore, the 2-parameter lognormal is superior to the normal model. Conclusions: Cath Lab procedures are well-modelled by lognormal models. This information helps to improve and to refine Cath Lab schedules and hence their efficient use.

    A compact UWB monopole antenna with penta band notched characteristics

    Get PDF
    A modified rectangular monopole ultra-wideband (UWB) antenna with penta notched frequency bands is presented. An inverted U shaped and slanted U-shaped on the radiating patch are inserted to achieve WiMAX and ARN bands rejection respectively, two mirrored summation Σ-shaped and four mirrored 5-shaped slots are inserted on the partial ground to achieve WLAN and X-band bands rejection respectively, finally rectangular shaped slot with partially open on the feed is inserted to achieve ITU-8 band rejection. The proposed antenna which was simulated has a compact size 30×35×1.6 m3. It is operated with impedance bandwidth 2.8-10.6 GHz at |S11| < −10 dB, that supported UWB bandwidth with filtering the five narrowbands that avoid the possible interference with them. The simulated resonant frequency for notched filters received 3.55, 4.55, 5.53, 7.45, 8.16 GHZ, for WiMAX, ARN, WLAN, X-Band, ITU-8 respectively. The proposed antenna is suitable for wireless communication such as mobile communication and internet of everything (IoE). Throughout this paper, CST-EM software package was used for the design implementation. Surface current distributions for all notched filters were investigated and shown that it is concentrated around the feeding point and the inserted notched slots proving that there is no radiation to the space due to maximum stored electromagnetic energy around each investigated notch slot, proving that the slots play a role of a quarter wavelength transformer which generates for each notched band, maximum gain, and radiation pattern are also investigated

    The effect of serum angiotensin II and angiotensin II type 1 receptor gene polymorphism on pediatric lupus nephritis

    Get PDF
    Background: Angiotensin II (Ang II) is found to perpetuate inflammation and visceral damage in systemic lupus erythematosus (SLE). It mediates most of its actions through Ang II receptor type I (AT1) whose gene polymorphism A1166C (CC genotype) seems to have pathogenic effects. Objective: To measure serum Ang II and the frequency of AT1 receptor CC genotype among a group of Egyptian patients with pediatric onset lupus nephritis (pLN). Methods: This is a case-control cross sectional study which included 24 patients with pLN and 24 age and sex-matched healthy subjects as controls. Clinical evaluation and routine laboratory markers for SLE patients were done. SLE disease activity index (SLEDAI) and the British Isles Lupus Assessment Group (BILAG)-2004 renal score were measured. Serum Ang II was measured by enzyme linked immunosorbent assay and detection of ATI receptor CC genotype by polymerase chain reaction were done for both patients and controls. Results: Patients had significantly higher serum Ang II than the controls (p=0.0001). The frequency of AT1 receptor CC genotype was significantly higher among patients as compared to the control group (p=0.008). Both serum Ang II and AT1 receptor CC genotype were comparable between patients with proliferative LN class III and IV and those with LN class II (p>0.05). Serum Ang II did not correlate significantly with SLEDAI or BILAG-renal score (p>0.05). Conclusion: Serum Ang II and AT1 receptor CC genotype seem to have pathogenic role in pLN but with no deleterious effects on the phenotype of LN for further assessment.Keywords: Lupus nephritis; Angiotensin II; Angiotensin II type 1 receptor; Polymorphism; Pediatrics

    A new method for voice signal features creation

    Get PDF
    Digital audio is one of the most important types of data at present. It is used in several applications, such as human knowledge and many security and banking applications. A digital voice signal is usually of a large size where the acoustic signal consists of a set of values distributed in one column (one channel) (mono signal) or distributed in two columns (two channels) (stereo signal), these values usually are the results of sampling and quantization of the original analogue voice signal. In this paper we will introduce a method which can be used to create a signature or key, which can be used later to identify or recognize the wave file. The proposed method will be implemented and tested to show the accuracy and flexibility of this method
    • …
    corecore